Wire Gauge Calculator

Wire has two limits: how much current it can carry without getting hot, and how much voltage it drops on the way. The calculator applies both and gives you the gauge to use.

Work it out

How this works

The two limits

Circular mils needed = 12 x current x length / allowable drop in volts. The constant 12 is for copper on a DC circuit, and the length is the one way distance in feet. The result is converted to an American Wire Gauge number.

Separately, the gauge has a maximum current rating. The answer is the thinner of the two limits, so a long run is usually set by voltage drop rather than by heating.

Worked example

One amp over ten feet at 12 V with a three percent drop allowed. The drop is 0.36 V, so the wire needs 12 x 1 x 10 / 0.36 = 333 circular mils. That calls for 24 AWG, which is rated for 3.5 A, so the current rating is not the problem here. The same one amp over a hundred feet needs 10 AWG.

Common mistake

Using the total length of the run when the formula wants the one way distance. Current goes out on one wire and back on the other, so a five foot pair of wires is a ten foot loop of resistance and the drop in each wire adds up.

Parts for this

These are the hookup wires the calculation asks for. Prices and availability are read live when this page is built.

Next step

ALAI is a member AI assistant and can be wrong. Digital VIP or an active TechCrate subscription is required for member answers. Low voltage hobby electronics only, no mains work.